Built-in computer automates calibration and measurement procedures.
Once you have introduced the solvent and oily water sample to
the unit, just push the START button. Everything is automated-from mixing and extracting
the oil components to measurement and drain. Calibration is a snap. Just introduce
deionized water in place of the oily water sample, and the OCMA-300 handles the automated
process for you.
(*1) Complete dispersion, mixing ,and extraction.
The extraction chamber uses HORIBA’s
special-design agitator blades. Just push the START button to initiate a powerful assure
proper measurement of your oil sample, the extraction time can be preset in 10-second
increments to any desired interval – from 10 seconds to
10 minutes.
(*2) Automatic fill and drain
The sample cell is filled and drained automatically by solenoid valves. There are
no clumsy manual valve to switch.
0-200mg/l dynamic range
A pyro-electric sensor gives you a full dynamic range from
0-200mg/l, with no need for range-switching. This makes the OCMA-300 perfect for fast,
accurate measurements of all types of samples, from low to high concentration.
Short warm-up time
Warms up in 20 minutes or less. This means you can get started with conventional
pneumatic NDIR analyzers is no longer necessary.
Optical adjustment unnecessary
The troublesome optical adjustments associated with conventional pneumatic NDIR
analyzers is no longer necessary.
Stable measurement
readout
The OCMA-300 determines automatically when the measured value has stabilized, and
holds that value for you. This means you always get consistent, stable data readouts.
Self-diagnosis function
The unit self-monitors for any possible problems, e.g., glitches during
measurement; deterioration of the light-source; or electrical problems. Should anything
out of the ordinary occur, you can spot it right away by a quick check of the warning
lamps and the linked on-screen error messages.
On-screen help and
warning messages
A wide range of helpful onscreen assistance-including operational instructions,
equipment status, and warning messages- streamlines all your measurement operations.
50 data sets in memory
With just the touch of a button you can input and recall up to 50 data sets. Each
data set includes measurement I.D. No., date and time of measurement, and measured value.
Extraction Solvent Type
S-316 extracts all oil components.
The OCMA-300 uses HORIBA’s special S-316 Solvent
to extract the oil components from the oily water sample. These are, then, measured by the
infrared-absorption method.
The two graphs at right show the absorption spectra of (1) petroleum and (2) Type S-316
Solvent does not absorb infrared radiation in the range of 3.4μm. Type S-316 Solvent does not absorb infrared radiation in this
range. As a result, if measurements are taken in the 3.4μm
range, all the oil components that have been extracted can be measured precisely, with
absolutely no influence from the presence of the S-316 Solvent.
Special syringe
measures out exact quantities of sample and solvent.
Not only does the OCMA-300’s unique
syringe-design assure you of exactly the right amount of oily water sample and solvent for
each measurement, now there is no longer any worry about contamination-error caused by
contact with the fingers.
RS-232C and parallel
printer ports
These ports link you to the world of MS-DOS computers and printers. The result?
Easy printouts and transfer of your OCMA-300-generated measurement data, plus remote
operation of the OCMA-300 right from your own PC keyboard. |